- BATTERIES & CABLES
- >
- US Battery 4Volt-US 2200 XC2
US Battery 4Volt-US 2200 XC2
SKU:
$155.00
$155.00
Unavailable
per item
Application: Wherever Deep Cycle 6-volt batteries are needed. Dimensions: 10-1/4 (260)L x 7-1/8 (181)W x 11-1/4 (286)H Type: Flooded Lead Acid (FLA) non-sealed. Case material: Polypropylene / Heat Sealed
Following is the charging recommendation and charging profile using 2 stage chargers for US Battery deep cycle products.
*Equalization and float charge modes are not considered to be one of the stages in a charging profile.
1. Bulk Charge Constant current @~10% of C/20 Ah in amps to 2.45+/-0.05 volts per cell (e.g. 7.35 volts +/-0.15 volts per 6 volt battery)
2. Absorption Charge Constant voltage (2.45+/-0.05 vpc) to 3% of C/20 Ah in amps then hold for 2-3 hours and terminate charge Charge termination can be by maximum time (2-4 hr) or dV/dt (4 mv/cell per hour)
• (Optional Float Charge) Constant voltage 2.17 vpc (6.51 volts per 6 volt battery) for unlimited time
• Equalization Charge Constant voltage (2.55+/-0.05 vpc) extended for 1-3 hours after normal charge cycle (repeat every 30 days)
Notes: Charge time from full discharge is 9-12 hours. Absorption charge time is determined by the battery but will usually be ~3 hours at 2.45 volts per cell. Float time is unlimited at 2.17 volts per cell. Specific gravity at full charge is 1.270 minimum
US 2200 XC2 SPECIFICATIONS
Standard AMP hrs Min @
1hr 2hr 5hr 6hr 10hr 20hr 48hr 72hr 100hr V Terminal (20 HR. RATE) 75 AMPS 56 AMPS 25 AMPS
133 152 181 187 206 232 246 252 258 6 UTL 232 122 175 474
Following is the charging recommendation and charging profile using 2 stage chargers for US Battery deep cycle products.
*Equalization and float charge modes are not considered to be one of the stages in a charging profile.
1. Bulk Charge Constant current @~10% of C/20 Ah in amps to 2.45+/-0.05 volts per cell (e.g. 7.35 volts +/-0.15 volts per 6 volt battery)
2. Absorption Charge Constant voltage (2.45+/-0.05 vpc) to 3% of C/20 Ah in amps then hold for 2-3 hours and terminate charge Charge termination can be by maximum time (2-4 hr) or dV/dt (4 mv/cell per hour)
• (Optional Float Charge) Constant voltage 2.17 vpc (6.51 volts per 6 volt battery) for unlimited time
• Equalization Charge Constant voltage (2.55+/-0.05 vpc) extended for 1-3 hours after normal charge cycle (repeat every 30 days)
Notes: Charge time from full discharge is 9-12 hours. Absorption charge time is determined by the battery but will usually be ~3 hours at 2.45 volts per cell. Float time is unlimited at 2.17 volts per cell. Specific gravity at full charge is 1.270 minimum
US 2200 XC2 SPECIFICATIONS
Standard AMP hrs Min @
1hr 2hr 5hr 6hr 10hr 20hr 48hr 72hr 100hr V Terminal (20 HR. RATE) 75 AMPS 56 AMPS 25 AMPS
133 152 181 187 206 232 246 252 258 6 UTL 232 122 175 474